Rexroth Imported Hydraulic Gear Pump for Steel Mill Industrial Use with 350MPA Maximum Load and 250L/min Speed Regulation

Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Rexroth Imported Hydraulic Gear Pump for Steel Mill Industrial Use with 350MPA Maximum Load and 250L/min Speed Regulation

  • 1
  • 2

Brand Name : PGH5-3X/200RE07VU2 PGH5-3X/200RE07VE4 PGH5-3X/200RR07VU2 PGH5-3X/250RE07VU2 PGH5-3X/250RE07VE4

Model Number : PGH5-3X/200RE07VU2 PGH5-3X/200RE07VE4 PGH5-3X/200RR07VU2 PGH5-3X/250RE07VU2 PGH5-3X/250RE07VE4

Certification : ISO

Place of Origin : Germany

MOQ : 1

Price : 2

Payment Terms : MoneyGram,Western Union,T/T,D/P,D/A,L/C

Supply Ability : 100

Delivery Time : 2 weeks

Packaging Details : wooden box

whatsapp : +85267220981

Email : Yli97584@gmail.com

Inlet Connection : Threaded or Flanged

Rotation : Clockwise or Counterclockwise

Pump : Rexroth

Material No : R902465419

Speed : Hydraulic oil, water ethylene glycol

Drive Mode : 6-250m3

Structure : Piston Pump

Standard Or Nonstandard : Standard

Contact Now

PGH5-3X/200RE07VU2
PGH5-3X/200RE07VE4
PGH5-3X/200RR07VU2
PGH5-3X/250RE07VU2
PGH5-3X/250RE07VE4 Steel mill industrial gear pump, Rexroth imported hydraulic quantitative pump from Germany

whatsapp: +85267220981 Email: Yli97584@mail.com
maximum load: 350MPA speed regulation range: 250L/min
control form: Hydraulic Control Applicable Industries: Machinery, Heavy Industry
Applicable Machinery: injection molding machine test scope: 180-680
degree of newness: brand new brand: Rexroth
Model: PGH5-3X/200RE07VU2
PGH5-3X/200RE07VE4
PGH5-3X/200RR07VU2
PGH5-3X/250RE07VU2
PGH5-3X/250RE07VE4
Packing: wooden box

Rexroth Imported Hydraulic Gear Pump for Steel Mill Industrial Use with 350MPA Maximum Load and 250L/min Speed Regulation

R900770179 PGH5-2X/250RE07WU2
R900766037 PGH2-2X/006RR07VU2-A334
R900754794 PGH4-2X/063RE07WE4
R900750708 PGH4-2X/020RE11WU2
R900750275 ABHAG-0100S41/PGH2-006/112M/61S/012B570A
R900932139 PGH4-2X/020RE11VU2
R900245596 PGH4-2X/025RE11VU2-A280B
R900204884 PGH5-2X/200RE07VE4-A388
R900064616 PGH3-1X/010LE07MU2
R900061672 PGH2-1X/006RE07ME4
R900057641 PGH5-2X/250RE07VU2-A388
R900086557 PGH5-2X/200RE07VE4
R900086556 PGH5-2X/160RE07VE4
R900086518 PGH5-2X/125RR11VU2
R900086321 PGH4-2X/040RE11VU2
R900951301 PGH2-2X/006RE07VU2
R900961549 PGH2-2X/006RR07VU2
R900961547 PGH2-2X/006LE07VU2
R900961560 PGH3-2X/013LR07VU2
R900086397 PGH4-2X/020RE11VE4
R900086356 PGH4-2X/020RR11VU2
R900086338 PGH4-2X/020LE11VU2
R900086379 PGH4-2X/020LR11VU2
R900086398 PGH4-2X/025RE11VE4
R900086357 PGH4-2X/025RR11VU2
R900086339 PGH4-2X/025LE11VU2
R900086380 PGH4-2X/025LR11VU2
R900086358 PGH4-2X/032RR11VU2
R900086340 PGH4-2X/032LE11VU2
R900086381 PGH4-2X/032LR11VU2
R900086359 PGH4-2X/040RR11VU2
R900086341 PGH4-2X/040LE11VU2
R900086382 PGH4-2X/040LR11VU2
R900086360 PGH4-2X/050RR11VU2
R900086342 PGH4-2X/050LE11VU2
R900086383 PGH4-2X/050LR11VU2
R900086325 PGH4-2X/063RE07VU2
R900086362 PGH4-2X/063RR07VU2
R900086344 PGH4-2X/063LE07VU2
R900086385 PGH4-2X/063LR07VU2
R900086326 PGH4-2X/080RE07VU2
R900086363 PGH4-2X/080RR07VU2
R900086345 PGH4-2X/080LE07VU2
R900086386 PGH4-2X/080LR07VU2
R900086405 PGH4-2X/100RE07VE4
R900086364 PGH4-2X/100RR07VU2
R900086346 PGH4-2X/100LE07VU2
R900086387 PGH4-2X/100LR07VU2
R900086551 PGH5-2X/063RE11VE4
R900932172 PGH5-2X/063RR11VU2
R900086496 PGH5-2X/063LE11VU2
R900086533 PGH5-2X/063LR11VU2
R900086460 PGH5-2X/080RE11VU2

R900086516 PGH5-2X/080RR11VU2
R900086497 PGH5-2X/080LE11VU2
R900086534 PGH5-2X/080LR11VU2
R900086498 PGH5-2X/100LE11VU2
R900932175 PGH5-2X/125RE11VE4
R900086536 PGH5-2X/125LR11VU2
R900086520 PGH5-2X/160RR07VU2
R900086501 PGH5-2X/160LE07VU2
R900086521 PGH5-2X/200RR07VU2
R900086503 PGH5-2X/200LE07VU2
R900086539 PGH5-2X/200LR07VU2
R900086466 PGH5-2X/250RE07VU2
R900086522 PGH5-2X/250RR07VU2
R900086504 PGH5-2X/250LE07VU2
R900086540 PGH5-2X/250LR07VU2
R901147122 PGH5-3X/063RE11VE4
R901147129 PGH5-3X/063RR11VU2
R901147123 PGH5-3X/080RE11VE4
R901147130 PGH5-3X/080RR11VU2
R901147124 PGH5-3X/100RE11VE4
R901147131 PGH5-3X/100RR11VU2
R901147118 PGH5-3X/125RE11VU2
R901147125 PGH5-3X/125RE11VE4
R901147132 PGH5-3X/125RR11VU2
R901147119 PGH5-3X/160RE11VU2
R901147126 PGH5-3X/160RE11VE4
R901147133 PGH5-3X/160RR11VU2
R901147120 PGH5-3X/200RE07VU2
R901147127 PGH5-3X/200RE07VE4

FAQ:

FAQ for PGH Series Gear Pumps

1. What core advantages make the PGH Series Gear Pumps suitable for industrial use?

The PGH Series stands out for its high pressure stability (supporting working pressures up to 250 bar for most models), compact structural design (saving installation space in hydraulic systems), and low noise operation (noise levels as low as 65 dB under rated conditions), making it ideal for continuous-duty industrial scenarios.

2. What precautions should be taken during the installation of PGH Series Gear Pumps?

• Ensure the pump’s rotational direction matches the system’s requirements (reverse rotation can cause internal component damage).

• Keep the suction line length within 1 meter and avoid sharp bends to prevent insufficient oil suction.

• Tighten the flange bolts to the torque specified in the manual (typically 18-22 N·m for standard models) to avoid oil leakage or housing deformation.

3. How to resolve abnormal noise from a PGH Series Gear Pump during operation?

It is recommended to use hydraulic oil that meets ISO VG 46 or ISO VG 68 specifications. The oil should have good anti-wear and anti-oxidation properties, and the oil temperature during operation should be controlled between -10°C and 80°C to avoid affecting pump performance.

4. How often should maintenance be performed on PGH Rexroth Gear Pumps?

For general industrial applications, routine inspection (checking oil level, temperature, and leakage) should be conducted monthly; oil change and filter replacement are recommended every 6 months or after 2000 hours of operation; a comprehensive disassembly and inspection of the pump should be carried out every 2-3 years.

5. Can PGH Rexroth Gear Pumps be used in high-temperature environments for a long time?

No. The maximum allowable long-term operating temperature of PGH Rexroth Gear Pumps is 80°C. Prolonged use in environments exceeding this temperature will accelerate the aging of internal seals and bearings, significantly reducing the pump's service life and even causing sudden failures.

I can further adjust the content of the FAQ according to specific application scenarios (such as adding questions about installation precautions) or translate it into Chinese. Do you need this service?


Product Tags:

350MPA Maximum Load Gear Pump

      

250L/min Speed Regulation Hydraulic Gear Pump

      

Steel Mill Industrial Rexroth Gear Pump

      
Cheap Rexroth Imported Hydraulic Gear Pump for Steel Mill Industrial Use with 350MPA Maximum Load and 250L/min Speed Regulation for sale

Rexroth Imported Hydraulic Gear Pump for Steel Mill Industrial Use with 350MPA Maximum Load and 250L/min Speed Regulation Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Quanzhou Yisenneng Hydraulic Electromechanical Equipment Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)